BS EN 60695-11-10 / IEC 60695-11-10 method A
BS EN 60695-11-10 / IEC 60695-11-10 method A involves horizontal test rate of burning and/or extent and time of burning of plastics in a horizontal position classification provided: HB, HB40 and HB75.
Specimen conditioning:Â Condition the specimens at 230C and relative humidity 50% for minimum of 48 hours.
Gas flow:Â Set the methane gas flow to 105 ml/min. Adjust the flow and air intakes of the burner to get a clean blue flame 20mm high.
Flame application:Â 20mm Bunsen burner flame.
Flame application time:Â 30 seconds. If the flame front reaches the first 25mm mark within 30 seconds the flame application is discontinued.
Measurements:
A – Whether the flame passed the 25mm mark.
B – Whether the flame passed the 100mm mark.
C – The elapsed time between 25mm and 100mm mark, if the flame passed the 100mm mark.
L – The damaged length between the 25mm and 100 mm mark.
V – The calculated liner burning rate in mm/min.
Based on the measured values use the following table to classify the material as HB, HB40 and HB75.
Test setup:Â The Bunsen Burner and the test specimen is set up as shown in the test schematic.